In the Desktop Tape Pack, remove the SCSI ID jumpers, orient the
Flex Cable as shown, and plug it into the SCSI ID jumper block.
Address Select Switch Cable
In the External Storage Module, orient the Address Select Switch
Cable as shown, and plug it into the SCSI ID jumper block.
Power
0.7 Amps @ +5Vdc
1.5 Amps @ +12Vdc
21.5 Watts
Jumper Settings
JUMPER
SETTING
DESCRIPTION
USAGE
RXD/TXD
Out
Serial Port
Not used
DIAG Parity
Out Out*
Normal/Diag Parity check
Not used Not used
CF2,CF1,CF 0
In
Disconnect Transfer Size
Size = 32K
JUMPER
TARGET 2
TARGET 3
TARGET 4
TARGET 5
ID2
Out
Out
In
In
ID1
In
In
Out
Out
ID0
Out
In
Out
In
1st SCSI
st3
st2
st0
st1
2nd SCSI
st7
st6
st2, st4
st3, st5
* IN for 370-1246
Note
The Cartridge Tape part number is 370-1203-01.
Reference
150MB 1/4-Inch Cartridge Tape Drive Configuration Manual for the
56-Inch Data Center Cabinet, 813-2076.